Products


Preview

Predision HESC-T-034 RS-232/RS-485 to 2-port RS-485 Hub
Manufacturer Part Number: HESC-T-034
Brand: Predision
$ 238.00
- Operating Temperature: -40°C to 85°C
- ±15 kV ESD Protection, 600 W Lightning Surge Protection per wire
- Isolation Voltage: 2,500 Vrms, 500 VDC (Continuous)
See our Shipping Policy for delivery regions and fees
Backordered
More stock available: May 29, 2026 (UTC-4)
Designed for mission-critical reliability in high-EMI environments, the HESC-T-034 features an industrial 10-pin Terminal Block interface for both RS-232C and RS-485 connections, ensuring secure and vibration-resistant wiring. This hub supports data rates up to 115.2 kbps and provides a robust electrical "Air-Gap" with 2,500 Vrms galvanic isolation and 600 W TVS surge protection per port.
Its intelligent Star-Topology management allows for seamless network segmentation; if one RS-485 branch fails, the hub automatically isolates the faulty segment, preventing a single-point failure from collapsing the entire bus. With integrated Automatic Data Direction Sensing and support for distances over 1,200 meters, the HESC-T-034 is the standard for highway tolling, grid monitoring, and large-scale industrial automation.
| Standard | RS-232C, RS-485 EIA/TIA |
| Electrical Interface | RS-232C: 10-pin Terminal Block |
| Interface Protection | RS-232: ±15 kV ESD Protection RS-485: 600 W Lightning Surge Protection per wire |
| Isolation Voltage | 2,500 Vrms, 500 VDC (Continuous), DC/DC module |
| Operating Mode | Asynchronous Half-duplex, Point-to-point |
| Operating Power | 9 - 30 VDC / 150 mA |
| Signal Indicators | 5 LEDs: Power (PWR), Transmit (TXD), Receive (RXD), Error (E1-E2) |
| Transmission Media | Twisted-pair (UTP) or Shielded Cable (STP) |
| Baud Rate | 300 bps - 115.2 kbps |
| Dimension | 120 x 80 x 25 mm |
| Operating Temperature | -40°C to 85°C |
| Relative Humidity | 5% to 95% (Non-condensing) |
| Transmission Distance | 5,000m(at 9,600 bps) |
Industrial RS-232 to 2-port RS-485 Converter with Optical Isolation, Baud Rate: 300 bps - 115.2 kbps, Power: 9-30 VDC/ 350 mA, Transmission Distance: 5,000m (at 9,600 bps), Isolation Voltage: 2,500 Vrms, 500 VDC (Continuous), DC/DC module, ±15 kV ESD Protection, 600 W Lightning Surge Protection per wire, Operating Temperature: -40℃ to 85℃.
Industrial RS-232/RS-485 to 2-port RS-485 Hub, Operating Power: 9-30 VDC / 150 mA, Baud Rate: 300 bps - 115.2 kbps, Transmission Distance: 5,000m (at 9,600 bps), Isolation Voltage: 2,500 Vrms, 500 VDC (Continuous), ±15 kV ESD Protection, 600 W Lightning Surge Protection per wire, Operating Temperature -40℃ to 85℃.
RS-232/RS-485 to 4-port RS-485 Hub (Din-rail), Operating Power: 9 - 30 VDC/150 mA, Baud Rate: 300 bps - 115.2 kbps, Transmission Distance: 5,000m (at 9,600 bps), Isolation Voltage: 2,500 Vrms, 500 VDC (Continuous), ±15 kV ESD Protection, 600W Lightning and Surge Protection per wire, Operating Temperature: -40℃ to 85℃.
Industrial RS-485/422 to 4-port RS-485/422 Hub, Baud Rate: 300 bps - 115.2 kbps, Operating Voltage: 9 - 48 VDC, Transmission Distance: 1,200m (at 9,600 bps), 8/20μs 3,000A Lightning Surge Protection per wire, Isolation Voltage: 2,500 Vrms, 500 VDC (Continuous), Operating Temperature: -40℃ to 85℃.
RS-232/485 to 4-port RS-485/422 Photoelectric Isolated Hub, Baud Rate: 300 bps - 115.2 kbps, Operating Voltage: 9 - 48 VDC, Transmission Distance: 1,200m (at 9,600 bps), 8/20μs 3,000A Lightning Surge Protection per wire, Isolation Voltage: 2,500 Vrms, 500 VDC (Continuous), Operating Temperature: -40℃ to 85℃.
RS-232/RS-485 to 8-port RS-485 Photoelectric Isolated Hub, Din-rail, Input Voltage: 12 - 48 VDC, Baud Rate: 300 bps - 115.2 kbps, Transmission Distance: 1,200m (at 9,600 bps), Isolation Voltage: 2,500 Vrms, 500 VDC (Continuous), 15 kV ESD Protection (RS-232), 1,500 W Lightning and Surge Protection per wire (RS-485), 2,000 V Lightning and Surge Protection (Power Supply), Operating Temperature: -40℃ to 85℃.
Industrial RS-232/RS-485 to 8-port RS-485 Hub, Baud Rate: 300 bps - 115.2 kbps, Transmission Distance: 5,000m (at 9,600 bps), Isolation Voltage: 2,500 Vrms, 500 VDC (Continuous), ±15 kV ESD Protection (RS-232), 1,500 W Lighting and Surge per wire (RS-485), Operating Temperature: -40℃ to 85℃.
Industrial Rack-mount RS-232/RS-485 to 8-port RS-485 Photoelectric Isolated Hub, 1U Enclosure, 100 - 240 VAC 50/60Hz, Baud Rate: 300 bps - 115.2 kbps, Transmission Distance: 5,000m (at 9,600 bps), Isolation Voltage: 2,500 Vrms 500 VDC (Continuous), ±15 kV ESD Protection (RS-232), 1,500 W Lighting and Surge per wire (RS-485), Operating Temperature: -40℃ to 85℃.
RS-232/RS-485 to 8-port RS-485 Photoelectric Isolated Hub, Baud Rate: 300 bps - 115.2 kbps, Transmission Distance: 5,000m (at 9,600 bps), Isolation Voltage: 2,500 Vrms, 500 VDC (Continuous), ±15 kV ESD Protection (RS-232), 1,500 W Lighting and Surge Protection per wire (RS-485), Operating Temperature: -40℃ to 85℃.
RS-232/RS-485 to 16-port RS-485 Photoelectric Isolated Hub, 1U Enclosure, Baud Rate: 300 bps - 115.2 kbps, Input Voltage: 100 - 240 VAC, 50/60 Hz, Transmission Distance: 5,000m (at 9,600 bps), Isolation Voltage: 2,500 Vrms, 500 VDC (Continuous), ±15 kV ESD Protection (RS-232), 1,500 W Lighting and Surge Protection per wire (RS-485), Operating Temperature: -40℃ to 85℃.
5-Year Warranty
24/7 Live Service
Global Support
Partner Privileges
OEM/ODM Available
Company Information
Contact Us
Our Address
11 Commerce St.
Norwalk, CT 06850
United States
Sign up for Our Newsletter
Career Opportunities
We make every effort to create a fair and productive workplace.
See our latest openings below!
Information & News
Shop With Confidence
Shop with the top ranking
payment platform
We accept Visa, Mastercard, American Express, Paypal, Company Purchase Orders
We're Here to Help!
Contact us and we'll get you to the right person as soon as possible!








Copyright © 2013-2026 Predision LLC. All Rights Reserved
Predision LLC - Authorized distributor of Henrich Electronics industrial Ethernet & IoT connectivity solutions














